i would like to use a timer but am now afraid to try another. Replaced complete new timer assuming 5 years perfect service probably wore it out. If the switch simply does not move side to side, it may be a bad clock, if you cannot see what is stopping it from moving. ft. 975 Telegraph Rd #103, Santa Paula, CA 93060 $409,000 MLS# V1-15365 Hillview Estates, where you own the land, and this one has a big lot, over 4,100. There is also a light switch for the lighting in the pool in the control panel and when i turn on the switch the light in the pool turns on. Advice? On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. Can breaker be bad? Some white lithium grease on the switch can help in some cases. Just installed a new timer. HELP! Any ideas? I used to run the pump for 8-9 hrs a day. OPEN TODAY, 12PM TO 3PM. Its hard to give a fixed order for the steps you should take as it depends on what you found in the previous steps. It seems flimsy when I click it onOnce on, it works like it should and shuts off every time. I have removed the ON TRIPPER and turn the motor on at the pump and it never trips the GFCI. I noticed that they had stopped. Does the manual lever stay in the on position always? It also provides a selectable voltage switch that enables you to choose between 120 and 240V, depending on what voltage you use and also has a battery backup option. Line is incoming, Load goes to the pump. Could I send you a picture of my setup? I have the PF1202T timer on my pool. Now, Im going to order some additional timer clips. 1-48 of 242 results for "pool timer trippers" RESULTS. To check this, try to pull out the clock dial and then move it to the correct time and press it back down again. Pool pump comes on fine with the on dog, but wont turn off. Deep down, I figured it was something I did wrong and it was. Reference Manual & Buyer's Guide Another Brick in the (For outside light timer) The one before was original to the house & I had no trouble. Wont power on pump but can hear timer clicking away. I think I have found it. After this has been removed, you can turn the breaker back on and measure for the voltage on the timer input. 220V clocks have 5 terminals, 110V clocks have 3 terminals. These are the trippers that came with the time clock. This will disengage the dial and allow you to spin it in either direction. If you look closely (with a flashlight and your glasses! "@type": "ImageObject",
Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. Thank you so much. Any ideas why its doing that? Hi David, I suppose that you could wire the T101 from the outlet, but Im not sure if that is in accordance with code. They are: Heres how to troubleshoot a mechanical pool timer step-by-step: It goes without saying that you should be qualified if you intend on working with live power. If the trippers are set for on and off pump function and nothing is working, reset the time and trippers. Use a power meter set on AC volts to verify the power is off, before handling the timer mechanism. Did the power recently go out or has the circuit breaker tripped? it could also be a failing breaker, but that would be a last resort. They are little ants that just came. Hello, I notice today that my pump wasnt running so I opened the pool breaker panel where the timer is and noticed the breaker was tripped. My timer runs, then after it reaches the off tripper, it stops, and never goes past the off tripper. Im wanting to use T101 to wire my above ground pool pump. There are 2 main facets to setting the mechanical timer for a pool pump, setting the time, and setting the on/off trippers. Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. Lately, the timer mechanism on my old T104R does not move. Remove the plastic insulator cover, and use an AC test meter to check for power on the terminals where the wires from the breaker connect to the time clock. If you dont have the voltage here you have an issue with either the wiring or the breaker. See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. They should be straight, if not, replace them. You need extreme care in this next step. Now it worksbut its really fast. MLS # 6354744 These nuts are designed to provide a precise amount of clamping force and ensure proper alignment of the rear suspension, so reusing them may compromise the safety and performance of your vehicle. the timer was directly plugged into a gfci and the pump directly into the timer. 2,767 Sq. If no damage is seen and the wires are intact, and the motor gears are not turning, and you find nothing stuck in the gears (sand, insects, any obstruction), and some spray WD-40 on the gears and a little push from a small flathead screwdriver does not help then, you can assume that the motor is dead, at which point you can replace the motor itself with the exact replacement, or replace the entire clock. I also dont see any ants or other insects. Hi Rhomell, are you sure you got the correct trippers? We may earn a small commission. A 50 hz timer would run faster on 60 hz, but the housing of my replacement motor says 60 hz and it is the correct replacement model. Karl, good question. Once you figure out what is wrong with the timer, you may be able to do the repair yourself or might have to hire an electrician to come and replace the timer for you. Thanks. The power should run from the breaker, to the timer, to the pump. You dont have two OFF trippers, right? Any advice on how to fix. Hi Bev, seems legit to me! Take them off and inspect them and look for twists in them. "identifier": ""
If your pool pump timer is beyond repair, call a professional to replace it. You will have live wires exposed and they can kill you if you touch them. Replace a new T104. Ive reset the time 5 times and just realized that its going counter clockwise. DEWENWILS Outdoor Outlet Box. "url": "https://blog.intheswim.com/"
Im ready to send my back for a replacement. These clocks determine when your pool pump turns on, and how long it runs. Jump to the troubleshooting steps below to fix the issue. Turn on / off manually work fine, but The clock gears still not moving. Are the trippers slid all the way onto the dial fully? I replaced a bad timer (90% sure I put the wires in the correct/same spots but there was one time when two wires got loose, so its possible I wired it wrong) and now it turns on and works, but the on/off switch doesnt work. Why it always stop around 10pm by itself and not moving again? Pump operates off schedule Power failure earlier Reset timer Breaker was OFF for some time Reset timer 4. Either that or if an older clock, the motor may be failing, or the switch mechanism worn (the part that is tripped by the tripper). Since it came out of the box today, it probably is not trash in the gears.It seems the plastic gears and/or the coil in the clock mechanism are not strong enough to engage the on/off points or not for long. You most likely just need to now set the pins and the clock and your timer will work. screwfindinganame on June 18, 2013 at 11:36 pm Hello Davy, Terry here again. With power off, you could also check the tightness of the on/off switch, it may be missing the tension spring also, check that its there. Stupid third question, but does the ON tripper say ON? For any wiring concerns, always refer to the wiring diagram printed on the inside of the timer door. "width": "611",
The problem lies, where the power dies, as they say, Thanks for the response. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. My timer doesnt seem to be working or my pump in either speed. "height": "219",
I fastened it very securely. TO SET TIME-OF-DAY:Pull CLOCK-DIALoutward. If they are not moving then you have an issue. Sometimes you will find the timer appears to be working, that is the clock dial is turning and you can see the gears behind the clock turning, but the pump isnt being switched on or off. If your Intermatic swimming pool timer has stopped working you will have to do something called troubleshooting. Now The ice and snow have melted and the cover is getting in deeper. My intermatic timer is about two years old as well. The gears on my timer motor are clearly turning, but when the timer dog reaches the power-on lever, the switch wont flip. If power is reaching the clock, and the gears are turning, but the dial is not turning this means the gear on the back of the dial is not engaged. Did you find the issue? There is no replacement on/off switch available, you would need a new T104 mechanism, unless you are able to melt some solder, or fix it with duct tape or something, lol! I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. The clock not turning on your Intermatic pool timer is a common issue. Use Green ON tripper for T100 Series timers and the silver ON tripper is for all other models. Donna Simpson Eating Website But What Toilet? My timer clock does not run and the manual on off switch does not turn off the pump motor. I can, however, hear an intermittent click as if the mechanism is trying to switch on. Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. Once you remove the water, you can use your pool brush on a pole, to gently push the pillows back to the center. Then after a bit, the pump restarts. Hi Matthew T104 can only turn one pump on and off. ), you should be able to discern if this is the problem, which could mean a new clock. I would shut off power to the clock while you spray, and release the tab at the top so you can spray behind the clock, and then find the nearby nest, and dig it up and add in some ant killer granular, or other method, to get the colony to move somewhere else. Hi Joe, could be time, for new timer. Hi Andy, when a clock is running slow, we might assume power outages, but when it runs fast, we might assume either a 60 hz (US) timeclock hooked up to 50 hz power service (Europe), or vice-versa, or a manufacturing defect in the gear tolerances could cause a synchronous motor timer to run fast.